Morbi, Gujarat
Technical details:
- Application: Spray Dryer.
- Capacity:
- Fuel Used: LPG
- Temperature: 640 deg. C
Pain Areas:
- Maintenance cost is high.
- Flame not matches as per application capacity.
- Temperature not achieve in required time.
Action taken by PES:
- Survey of Site.
- Convey customer for Duct Burner.
- After calculations of applications requirement PES suggest ESX120 Burner.
Based on application capacity, PES suggested the solution for combustion system comprising of:
- Nu-way Burner ESX120
- Mounting Plate.
- Gas Train with pilot.
- Control Panel.
Results:
Savings in fuel consumption.
Reduced time to attain temperature.
Low maintenance cost.
Neat & Clean floor.